The Solar Spring motor runs in a dry environment and it is important
that water be kept out of the motor chamber. The cable joint in the motor
shroud (358) must be carefully protected at all times in such manner as to be
completely water-tight. The pump is supplied with a length of special neoprene
electric cable which is specially sealed a) individual wire to wire sheath, b)
individual wire sheaths to external sheath and c) external sheath to the cable
guide in the motor shroud (358).
Should it ever be necessary to separate the electric cable from the motor
shroud (358) the following procedure must be carefully followed :
Tools and materials required : Heat gun, cable stripper
Soldering
sleeve 1) Cut the cable (363) and make a "fresh" end and clean the
cable guide on the motor shroud (358)
2) Strip the outer sheath off the last 20cm of the cable (363)
3) Slide a 20cm length of self-welding sleeve (---) onto the cable (363)
4) Slide a cable stop "O" ring ( ---) onto the cable (363)
5) Push the cable (363) into the cable guide in the motor shroud (358) so that
the outer sheath of the cable enters the cable guide.
(Drawing)
6)
Weld the shroud end of the self welding sleeve (---) onto the cable guide along
the whole length of the cable guide.
7) Fit the cable "O" ring (---) under the self-welding sleeve (---)
at a position about 3 centimetres from the un-welded end of the cable sleeve
(---)
(Drawing)
8) Weld the rest of the self-welding sleeve (---) onto the electric cable (363)
and over the cable "O" ring (---).
(Drawing)
Note
: The cable "O" ring serves as a stop, to protect the cable terminals
should weight accidentally end up on the electrical cable
(Schematic drawing showing wires, colours and terminal positions)
(There
are drawings in the installation instructions)
Menu for the maintenance of Solar Spring pumps.
Some recommended technologies,
List of attachments to the Model.
Typical list of graphs and
drawings.
List of abbreviations used.
List of key words.
Documents for funding
applications.