Homepage

The Model

Draft projects

Articles published

Technologies

Annexed material

Downloads

 About Bakens Verzet

T.E.MANNING

Schoener 50
1771 ED Wieringerwerf
The Netherlands
Tel/fax 0031-227-604128
Homepage: http://www.flowman.nl
E-mail:pumps@flowman.nl

FLOWMAN

ADVANCED PUMP TECHNOLOGIES

Edition 02: 08 March, 2002


SOLAR SPRING SOLAR PUMPS

MAINTENANCE

Maintenance of the electric cable

The Solar Spring motor runs in a dry environment and it is important that water be kept out of the motor chamber. The cable joint in the motor shroud (358) must be carefully protected at all times in such manner as to be completely water-tight. The pump is supplied with a length of special neoprene electric cable which is specially sealed a) individual wire to wire sheath, b) individual wire sheaths to external sheath and c) external sheath to the cable guide in the motor shroud (358).
Should it ever be necessary to separate the electric cable from the motor shroud (358) the following procedure must be carefully followed :

How to solder the electric cable to the motor shroud (358)

Tools and materials required : Heat gun, cable stripper

Soldering sleeve 1) Cut the cable (363) and make a "fresh" end and clean the cable guide on the motor shroud (358)
2) Strip the outer sheath off the last 20cm of the cable (363)
3) Slide a 20cm length of self-welding sleeve (---) onto the cable (363)
4) Slide a cable stop "O" ring ( ---) onto the cable (363)
5) Push the cable (363) into the cable guide in the motor shroud (358) so that the outer sheath of the cable enters the cable guide.

(Drawing)

6) Weld the shroud end of the self welding sleeve (---) onto the cable guide along the whole length of the cable guide.
7) Fit the cable "O" ring (---) under the self-welding sleeve (---) at a position about 3 centimetres from the unwelded end of the cable sleeve (---)

(Drawing)
8) Weld the rest of the self-welding sleeve (---) onto the electric cable (363) and over the cable "O" ring (---).

(Drawing)

Note : The cable "O" ring serves as a stop, to protect the cable terminals should weight accidentally end up on the electrical cable

Connection of cable to motor

(Schematic drawing showing wires, colours and terminal positions)

(There are drawings in the installation instructions)


RETURN TO LIST OF CONTENTS: Solar Spring Maintenance manual.

RETURN TO SELF DIAGNOSTICS for Maintenance purpose

RETURN TO KEY WORDS: Solar Spring Maintenance manual.

RETURN TO DRAWING: Drawing for maintenance purposes.


RETURN TO SOLAR SPRING: General index


RETURN TO:

PRODUCTS OFFERED