Director,
T.E.(Terry)
Manning,
Schoener 50,
1771 ED
Wieringerwerf,
The
Tel:
0031-227-604128
Homepage:
http://www.flowman.nl
E-mail:
(nameatendofline)@xs4all.nl : bakensverzet
Incorporating
innovative social, financial, economic, local administrative and productive
structures, numerous renewable energy applications, with an important role for
women in poverty alleviation in rural and poor urban environments.
"Money is not
the key that opens the gates of the market but the bolt that bars them"
Gesell, Silvio The
Natural Economic Order
Revised English
edition, Peter Owen, London 1958, page 228
Edition 22:
INDICATIVE CAPACITY CHARTS FOR 2.0MM CAM SHAFTS
All rights
to modify technical specifications and performance characteristics without
notice are reserved.
2 pistons 48V, 200W nominal motor, with cam 2.0mm
4x65Wp panels; insolation 1000-1100Ws/m2
H/m(in meters) |
Use |
MaxQ (liters/hour) |
Summer (liters/day) |
Winter (liters per day) |
Average (liters/day) |
000 |
+++++ |
00720 |
07300 |
05300 |
06300 |
010 |
+++++ |
00670 |
06600 |
04800 |
05700 |
020 |
+++++ |
00620 |
05900 |
04300 |
05100 |
030 |
+++++ |
00570 |
05300 |
03900 |
04600 |
040 |
+++++ |
00520 |
04700 |
03400 |
04050 |
050 |
+++++ |
00480 |
04200 |
03000 |
03600 |
060 |
***** |
00450 |
03900 |
02800 |
03350 |
070 |
***** |
00420 |
03600 |
02600 |
03100 |
080 |
***** |
00400 |
03300 |
02400 |
02850 |
090 |
***** |
00380 |
03000 |
02200 |
02600 |
100 |
***** |
00360 |
02800 |
02000 |
02400 |
110 |
***** |
00340 |
02600 |
01900 |
02250 |
120 |
***** |
00320 |
02400 |
01700 |
02050 |
130 |
***** |
00300 |
02200 |
01600 |
01900 |
140 |
***** |
00290 |
02100 |
01500 |
01800 |
150 |
***** |
00280 |
02000 |
01400 |
01700 |
2 pistons 48V, 200W nominal motor, with cam 2.0mm
4x65Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day
Use:+++++possible (NOT
RECOMMENDED),*****optimal.
Height(meters) |
Use |
MaxQ (liters/hour) |
Liters per day |
|||
000 |
***** |
00700 |
06900 |
|
||
025 |
***** |
00550 |
04800 |
|
||
050 |
***** |
00460 |
03600 |
|
||
075 |
***** |
00390 |
02700 |
|
||
100 |
***** |
00330 |
02200 |
|
||
150 |
***** |
00230 |
01400 |
|
||
Winter
conditions are 5.2Kwh/day and capacities are about 73% of the summer
capacities |
||||||
Solar
Spring pumps are true piston pumps and their capacity is linear (+/-10%) to
the insolation. To calculate capacity for other latitudes multiply daily
insolation as above by the average daily insolation at the site in question,
then apply the capacities in the table to the result. |
||||||
2 pistons
48V, 200W nominal motor, with cam 2.0mm
4x50Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day
Use:+++++possible (NOT
RECOMMENDED),*****optimal.
Height(meters) |
Use |
MaxQ (liters/hour) |
Liters per day |
000 |
***** |
00690 |
06500 |
025 |
***** |
00520 |
04200 |
050 |
***** |
00420 |
02900 |
075 |
***** |
00300 |
01900 |
100 |
+++++ |
00180 |
01400 |
Winter conditions are 5.2Kwh/day and capacities are
about 73% of the summer capacities |
|||
Solar Spring pumps are true piston pumps and their
capacity is linear (+/-10%) to the insolation. To calculate capacity for
other latitudes multiply daily insolation as above by the average daily
insolation at the site in question, then apply the capacities in the table to
the result. |
2 pistons
48V, 200W nominal motor, with cam 2.0mm
2x12V batteries = 24V
Use:+++++possible (NOT
RECOMMENDED),*****optimal.
Height(meters) |
Use |
MaxQ (liters/hour) |
Amperes |
000 |
***** |
00280 |
0.9 |
025 |
***** |
00210 |
1.3 |
050 |
***** |
00170 |
1.9 |
075 |
***** |
00160 |
2.3 |
100 |
***** |
00130 |
2.7 |
150 |
***** |
00100 |
3.2 |
|
20V |
30V |
||||
H/meters |
AMP |
L/H |
EFF% |
AMP |
L/H |
EFF% |
000 |
0.8 |
0210 |
00 |
0.9 |
0380 |
00 |
050 |
1.8 |
0140 |
53 |
1.9 |
0230 |
55 |
100 |
2.6 |
0110 |
58 |
2.7 |
0170 |
57 |
150 |
3.1 |
0090 |
59 |
3.2 |
0130 |
56 |
200 |
0.0 |
0000 |
00 |
3.4 |
0100 |
54 |
|
40V |
50V |
||||
H/meters |
AMP |
L/H |
EFF% |
AMP |
L/H |
EFF% |
000 |
1.0 |
0450 |
00 |
1.1 |
0510 |
00 |
050 |
2.1 |
0300 |
49 |
2.3 |
0370 |
45 |
100 |
2.9 |
0230 |
55 |
3.0 |
0290 |
54 |
150 |
3.3 |
0180 |
56 |
3.4 |
0230 |
55 |
200 |
3.5 |
0130 |
51 |
3.6 |
0170 |
51 |
|
60V |
70V |
||||
H/meters |
AMP |
L/H |
EFF% |
AMP |
L/H |
EFF% |
000 |
1.3 |
0630 |
00 |
1.4 |
0740 |
00 |
050 |
2.4 |
0430 |
42 |
2.4 |
0480 |
39 |
100 |
3.1 |
0340 |
50 |
3.2 |
0390 |
48 |
150 |
3.5 |
0270 |
53 |
3.6 |
0310 |
51 |
200 |
3.7 |
0210 |
52 |
3.8 |
0240 |
50 |
Index
of performance tables.
Tables for 3.0mm cams.
Tables for 2.6mm cams.
Tables for 2.2mm cams.
List of attachments to the Model.
Typical list of graphs and
drawings.
List of abbreviations used.
List of key words.