Use: +++++ possible, ***** optimal.
H/m(in meters) | Use | MaxQ (liters/hour) | Summer (liters/day) | Winter (liters per day) | Average (liters/day) |
---|---|---|---|---|---|
000 | ***** | 00980 | 09600 | 07000 | 08300 |
010 | ***** | 00910 | 08600 | 06300 | 07450 |
020 | ***** | 00840 | 07600 | 05500 | 06550 |
030 | ***** | 00790 | 06800 | 04900 | 05850 |
040 | ***** | 00750 | 06200 | 04500 | 05350 |
050 | ***** | 00710 | 05600 | 04100 | 04850 |
060 | ***** | 00660 | 05000 | 03600 | 04300 |
070 | ***** | 00610 | 04400 | 03200 | 03800 |
80m and over | Not recommended |
Use:+++++possible (NOT RECOMMENDED),*****optimal.
Height(meters) | Use | MaxQ (liters/hour) | Liters per day |
---|---|---|---|
000 | ***** | 00950 | 08800 |
025 | ***** | 00770 | 06100 |
050 | ***** | 00660 | 04500 |
075 | ***** | 00370 | 02600 |
100 | +++++ | 00290 | 04500 |
60m and over | Not recommended | ||
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities | |||
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result. |
Use:+++++possible (NOT RECOMMENDED),*****optimal.
Height(meters) | Use | MaxQ (liters/hour) | Liters per day |
---|---|---|---|
000 | ***** | 00920 | 08000 |
025 | ***** | 00700 | 04900 |
050 | +++++ | 00360 | 02800 |
60m and over | Not recommended | ||
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities | |||
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result. |
Use:+++++possible (NOT RECOMMENDED),*****optimal.
Height(meters) | Use | MaxQ (liters/hour) | Amperes |
---|---|---|---|
000 | ***** | 00460 | 1.1 |
025 | ***** | 00320 | 2.1 |
050 | ***** | 00240 | 3.0 |
075 | ***** | 00200 | 4.1 |
20V | 30V | |||||
---|---|---|---|---|---|---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% |
000 | 1.0 | 0440 | 00 | 1.1 | 0510 | 00 |
025 | 1.9 | 0250 | 45 | 2.1 | 0375 | 42 |
050 | 3.1 | 0190 | 42 | 2.8 | 0330 | 55 |
075 | 4.5 | 0150 | 34 | 3.6 | 0290 | 55 |
100 | 0.0 | 0000 | 00 | 4.4 | 0260 | 54 |
40V | 50V | ||||||
---|---|---|---|---|---|---|---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% | |
000 | 1.3 | 0600 | 00 | 1.5 | 0740 | 00 | |
025 | 2.2 | 0500 | 39 | 2.4 | 0620 | 35 | |
050 | 3.1 | 0450 | 50 | 3.1 | 0550 | 49 | |
075 | 3.9 | 0400 | 53 | 4.0 | 0500 | 51 | |
100 | 4.5 | 0360 | 55 | 4.5 | 0450 | 55 | |
90m | The pump should NOT be used at 40V/50V! |
60V | 70V | ||||||
---|---|---|---|---|---|---|---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% | |
000 | 1.6 | 0855 | 00 | 1.9 | 0920 | 00 | |
025 | 2.4 | 0720 | 35 | 2.7 | 0820 | 30 | |
050 | 3.1 | 0660 | 49 | 3.3 | 0750 | 44 | |
075 | 3.8 | 0570 | 51 | 4.1 | 0680 | 49 | |
100 | 4.5 | 0530 | 54 | 4.9 | 0640 | 51 | |
90m | The pump should NOT be used at 60V! | ||||||
80m | Note:the pump should NOT be used at 70V! |