SOLAR SPRING SOLAR PUMPS


Preliminary note

Solar installations are influenced by numerous local environmental and system factors, which are such that any table of performances and capacities must be considered indicative only. By way of example, voltage loss along the supply cable can reduce the real voltage available at the pump, so that the performance of one pump fitted with a long supply cable will necessarily be lower than that of another pump using a shorter supply line, even though the actual head may be the same for both units. Similar factors may affect the areas of application of the pumps. Low voltage systems, such for example, as two panel or 24V battery driven systems, may show proportionately greater sensitivity to local environmental and system factors than 48V four panel systems. Should you have any doubts about a given installation please contact E-mail Terry Manning or your local Solar Spring distributor for more information.
All rights to modify technical specifications and performance characteristics without notice are reserved.

PERFORMANCE TABLES FOR 2.6MM CAMS

Indicative daily capacity without Hyboost but with Sunprimer MkII

2 pistons 48V, 200W nominal motor, with cam 2.6mm 4x65Wp panels; insolation 1000-1100Ws/m2

Use: +++++ possible, ***** optimal.

H/m(in meters)UseMaxQ (liters/hour)Summer (liters/day)Winter (liters per day)Average (liters/day)
000*****00980096000700008300
010*****00910086000630007450
020*****00840076000550006550
030*****00790068000490005850
040*****00750062000450005350
050*****00710056000410004850
060*****00660050000360004300
070*****00610044000320003800
80m and overNot recommended


PERFORMANCE TABLES

PERFORMANCE:INDICATIVE DAILY CAPACITY

Indicative daily capacity with Sunprimer Mk II

2 pistons 48V, 200W nominal motor, with cam 2.6mm
4x65Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day

Use:+++++possible (NOT RECOMMENDED),*****optimal.

Height(meters)UseMaxQ (liters/hour)Liters per day
000*****0095008800
025*****0077006100
050*****0066004500
075*****0037002600
100+++++0029004500
60m and overNot recommended
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result.


PERFORMANCE TABLES

PERFORMANCE:INDICATIVE DAILY CAPACITY

Indicative daily capacity with Sunprimer Mk II

2 pistons with 48V, 200W nominal motor, with cam 2.6mm
4x50Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day

Use:+++++possible (NOT RECOMMENDED),*****optimal.

Height(meters)UseMaxQ (liters/hour)Liters per day
000*****0092008000
025*****0070004900
050+++++0036002800
60m and overNot recommended
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result.


PERFORMANCE TABLES

PERFORMANCE:INDICATIVE DAILY CAPACITY

Indicative daily capacity WITHOUT Sunprimer controller

2 pistons with 48V, 200W nominal motor, with cam 2.6mm
2x12V batteries = 24V

Use:+++++possible (NOT RECOMMENDED),*****optimal.

Height(meters)UseMaxQ (liters/hour)Amperes
000*****004601.1
025*****003202.1
050*****002403.0
075*****002004.1


Performance table with Sunprimer Mk II without Hyboost

2 pistons with 48V, 200W nominal motor, with cam 2.6

20V30V
H/metersAMPL/HEFF%AMPL/HEFF%
0001.00440001.1051000
0251.90250452.1037542
0503.10190422.8033055
0754.50150343.6029055
1000.00000004.4026054

40V50V
H/metersAMPL/HEFF%AMPL/HEFF%
0001.30600001.5074000
0252.20500392.4062035
0503.10450503.1055049
0753.90400534.0050051
1004.50360554.5045055
90m The pump should NOT be used at 40V/50V!

60V70V
H/metersAMPL/HEFF%AMPL/HEFF%
0001.60855001.9092000
0252.40720352.7082030
0503.10660493.3075044
0753.80570514.1068049
1004.50530544.9064051
90m The pump should NOT be used at 60V!
80m Note:the pump should NOT be used at 70V!

RETURN TO:

INDEX TO PERFORMANCE TABLES>
Tables for 3.0mm cams
Tables for 2.2mm cams
Tables for 2.0mm cams

RETURN TO:

GENERAL COVER PAGE
PRESENTATION OF SOLAR SPRING PUMPS
PHOTOGRAPH AND DRAWING OF THE SOLAR SPRING PUMPS