SOLAR SPRING SOLAR PUMPS
Preliminary note
Solar installations are influenced by numerous local environmental and system factors, which are such that any table of performances and capacities must be considered indicative only. By way of example, voltage loss along the supply cable can reduce the real voltage available at the pump, so that the performance of one pump fitted with a long supply cable will necessarily be lower than that of another pump using a shorter supply line, even though the actual head may be the same for both units. Similar factors may affect the areas of application of the pumps. Low voltage systems, such for example, as two panel or 24V battery driven systems, may show proportionately greater sensitivity to local environmental and system factors than 48V four panel systems. Should you have any doubts about a given installation please contact
E-mail Terry Manning or your local Solar Spring distributor for more information.
All rights to modify technical specifications and performance characteristics without notice are reserved.
PERFORMANCE TABLES FOR 2.2MM CAMS
Indicative daily capacity without Hyboost but with Sunprimer MkII
2 pistons 48V, 200W nominal motor, with cam 2.2mm
4x65Wp panels; insolation 1000-1100Ws/m2
H/m(in meters) | Use | MaxQ (liters/hour) | Summer (liters/day) | Winter (liters per day) | Average (liters/day) |
---|
000 | +++++ | 00860 | 08700 | 06300 | 07500 |
010 | +++++ | 00820 | 07900 | 07500 | 06800 |
020 | +++++ | 00780 | 07100 | 05100 | 06100 |
030 | +++++ | 00730 | 06400 | 04600 | 05500 |
040 | +++++ | 00670 | 05700 | 04100 | 04900 |
050 | +++++ | 00620 | 05000 | 03600 | 04300 |
060 | ***** | 00590 | 04600 | 03300 | 03950 |
070 | ***** | 00560 | 04200 | 03000 | 03600 |
080 | ***** | 00530 | 03800 | 02800 | 03300 |
090 | ***** | 00480 | 03300 | 02400 | 02850 |
100 | ***** | 00440 | 02900 | 02100 | 02500 |
110m and over | Not recommended |
PERFORMANCE TABLES
PERFORMANCE:INDICATIVE DAILY CAPACITY
Indicative daily capacity with Sunprimer MkII
2 pistons 48V, 200W nominal motor, with cam 2.2mm
4x65Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day
Use:+++++possible (NOT RECOMMENDED),*****optimal.
Height(meters) | Use | MaxQ (liters/hour) | Liters per day |
---|
000 | ***** | 00840 | 08100 |
025 | ***** | 00710 | 05900 |
050 | ***** | 00580 | 04100 |
075 | ***** | 00480 | 03000 |
100 | ***** | 00250 | 01900 |
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities |
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result. |
PERFORMANCE TABLES
PERFORMANCE:INDICATIVE DAILY CAPACITY
Indicative daily capacity with Sunprimer MkII
2 pistons 48V, 200W nominal motor, with cam 2.2mm
4x50Wp panels; insolation for 40 degrees North. Summer conditions 7kWh/day
Use:+++++possible (NOT RECOMMENDED),*****optimal.
Height(meters) | Use | MaxQ (liters/hour) | Liters per day |
---|
000 | ***** | 00820 | 07300 |
025 | ***** | 00670 | 04800 |
050 | +++++ | 00440 | 02800 |
Winter conditions are 5.2Kwh/day and capacities are about 73% of the summer capacities |
Solar Spring pumps are true piston pumps and their capacity is linear (+/-10%) to the insolation. To calculate capacity for other latitudes multiply daily insolation as above by the average daily insolation at the site in question, then apply the capacities in the table to the result. |
Performance table with Sunprimer MkII without Hyboost
2 pistons 48V, 200W nominal motor, with cam 2.2
| 20V | 30V |
---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% |
---|
000 | 0.9 | 0350 | 00 | 1.0 | 0460 | 00 |
025 | 1.6 | 0190 | 42 | 1.8 | 0320 | 42 |
050 | 2.2 | 0150 | 46 | 2.4 | 0290 | 55 |
075 | 2.8 | 0140 | 51 | 2.9 | 0230 | 54 |
100 | 3.5 | 0130 | 51 | 3.6 | 0210 | 53 |
| 40V | 50V |
---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% |
---|
000 | 1.2 | 0540 | 00 | 1.3 | 0640 | 00 |
025 | 2.0 | 0450 | 39 | 2.2 | 0550 | 35 |
050 | 2.7 | 0390 | 50 | 2.8 | 0480 | 47 |
075 | 3.2 | 0330 | 54 | 3.4 | 0440 | 54 |
100 | 3.7 | 0290 | 54 | 3.8 | 0370 | 53 |
| 60V | 70V |
---|
H/meters | AMP | L/H | EFF% | AMP | L/H | EFF% |
---|
000 | 1.5 | 0750 | 00 | 1.7 | 0860 | 00 |
025 | 2.3 | 0670 | 34 | 2.4 | 0740 | 31 |
050 | 2.9 | 0570 | 45 | 3.0 | 0670 | 43 |
075 | 3.5 | 0520 | 51 | 3.6 | 0590 | 49 |
100 | 3.9 | 0440 | 52 | 4.1 | 0520 | 50 |
RETURN TO:
INDEX OF PERFORMANCE TABLES
Tables for 3.0mm cams
Tables for 2.6mm cams
Tables for 2.0mm cams
RETURN TO:
GENERAL COVER PAGE
PRESENTATION OF SOLAR SPRING PUMPS
PHOTOGRAPH AND DRAWING OF THE SOLAR SPRING PUMPS
INSTALLATION OF SOLAR SPRING PUMPS
MAINTENANCEOF SOLAR SPRING PUMPS